Visible light photon counters optimization for quantum information applications
Description
In this paper we describe the studies of the main parameters needed for optimal operation of Visible Light Photon Counters (VLPCs) when used in quantum information systems. The isolation of the single photon signal is analyzed through the definition of a contamination parameter. A compromise in the minimization of this parameter for temperature, bias voltage and dark count variation must be achieved and this depends on the experimental conditions
Availability note (English)
Available from http://lss.fnal.gov/cgi-bin/find_paper.pl?pub-06-379.pdf; PURL: https://www.osti.gov/servlets/purl/897157-t6Ja7o/Additional details