Arkansas Nuclear One Unit one risk analysis results
Description
This paper presents the results of the analysis of Arkansas Nuclear One Unit One nuclear power plant which was performed as part of the Interim Reliability Evaluation Program (IREP). ANO-1 is a Babcock and Wilcox pressurized water reactor. The IREP has several objectives, three of which are achieved by the analysis presented in this paper. The three objectives met are: (1) the identification of those accident sequences which are expected to dominate the public health and safety risks associated with operation of ANO-1, (2) the development of state-of-the-art plant system models which can be used as a foundation for subsequent, more intensive applications of probabilistic risk assessment on ANO-1, and (3) the increase in number of experienced practitioners of probabilistic risk assessment. The estimated core melt frequency for ANO-1 is similar to values predicted by probabilistic risk assessments of other light water reactors
Additional details
Publishing Information
- Imprint Title
- Proceedings of the international meeting on thermal nuclear reactor safety. Vol. 2
- Journal Page Range
- p. 1125-1133.
- Report number
- NUREG/CP--0027-Vol.2
Conference
- Title
- International meeting on thermal nuclear reactor safety (ANS topical meeting).
- Dates
- 29 Aug - 2 Sep 1982.
- Place
- Chicago, IL (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 14792423
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ARKANSAS-1 REACTOR; FAILURE MODE ANALYSIS; REACTOR ACCIDENTS; REACTOR SAFETY; RISK ANALYSIS
- Descriptors DEC
- ACCIDENTS; ENRICHED URANIUM REACTORS; POWER REACTORS; PWR TYPE REACTORS; REACTORS; SAFETY; SYSTEM FAILURE ANALYSIS; SYSTEMS ANALYSIS; WATER COOLED REACTORS; WATER MODERATED REACTORS