Temperature variation of the refractive indices of yttrium lithium fluoride

  • 1. University of California, Los Alamos Scientific Laboratory, P.O. Box 1663, Los Alamos, New Mexico 87545

Description

The temperature variations of the refractive indices of LiYF4, YLF, have been measured in the visible region of the spectrum. The temperature variation at 0.546 μm are -0.67 x 10-6/0C and -2.30 x 10-6/0C for the ordinary and extraordinary refractive indices, respectively. A Sellmeier equation was fit to more extensive room-temperature refractive-index data measured elsewhere

Additional details

Publishing Information

Journal Title
J. Opt. Soc. Am.
Journal Volume
70
Journal Issue
10
Series
J. Opt. Soc. Am.
Journal Page Range
1244-1247