Monte Carlo electron-trajectory simulations in bright-field and dark-field STEM: Implications for tomography of thick biological sections
- 1. Laboratory of Bioengineering and Physical Science, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bldg. 13, Rm. 3N17, 13 South Drive, Bethesda, MD 20892-5766 (United States)
Description
A Monte Carlo electron-trajectory calculation has been implemented to assess the optimal detector configuration for scanning transmission electron microscopy (STEM) tomography of thick biological sections. By modeling specimens containing 2 and 3 at% osmium in a carbon matrix, it was found that for 1-μm-thick samples the bright-field (BF) and annular dark-field (ADF) signals give similar contrast and signal-to-noise ratio provided the ADF inner angle and BF outer angle are chosen optimally. Spatial resolution in STEM imaging of thick sections is compromised by multiple elastic scattering which results in a spread of scattering angles and thus a spread in lateral distances of the electrons leaving the bottom surface. However, the simulations reveal that a large fraction of these multiply scattered electrons are excluded from the BF detector, which results in higher spatial resolution in BF than in high-angle ADF images for objects situated towards the bottom of the sample. The calculations imply that STEM electron tomography of thick sections should be performed using a BF rather than an ADF detector. This advantage was verified by recording simultaneous BF and high-angle ADF STEM tomographic tilt series from a stained 600-nm-thick section of C. elegans. It was found that loss of spatial resolution occurred markedly at the bottom surface of the specimen in the ADF STEM but significantly less in the BF STEM tomographic reconstruction. Our results indicate that it might be feasible to use BF STEM tomography to determine the 3D structure of whole eukaryotic microorganisms prepared by freeze-substitution, embedding, and sectioning.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.ultramic.2008.10.005Additional details
Identifiers
- DOI
- 10.1016/j.ultramic.2008.10.005;
- PII
- S0304-3991(08)00267-2;
Publishing Information
- Journal Title
- Ultramicroscopy (Amsterdam)
- Journal Volume
- 109
- Journal Issue
- 3
- Journal Page Range
- p. 213-221
- ISSN
- 0304-3991
- CODEN
- ULTRD6
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 41009613
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- CARBON; COMPUTERIZED SIMULATION; ELASTIC SCATTERING; ELECTRONS; IMAGES; LOSSES; MICROORGANISMS; MONTE CARLO METHOD; OSMIUM; SIGNALS; SIGNAL-TO-NOISE RATIO; SPATIAL RESOLUTION; SURFACES; TOMOGRAPHY; TRAJECTORIES; TRANSMISSION ELECTRON MICROSCOPY
- Descriptors DEC
- CALCULATION METHODS; DIAGNOSTIC TECHNIQUES; DIMENSIONLESS NUMBERS; ELECTRON MICROSCOPY; ELEMENTARY PARTICLES; ELEMENTS; FERMIONS; LEPTONS; METALS; MICROSCOPY; NONMETALS; PLATINUM METALS; REFRACTORY METALS; RESOLUTION; SCATTERING; SIMULATION; TRANSITION ELEMENTS
Optional Information
- Copyright
- Copyright (c) 2008 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.