Published 1991 | Version v1
Miscellaneous

Determination of uranium in sea water by adsorptive differential pulse voltametry

  • 1. Bhabha Atomic Research Centre, Bombay (India). Pollution Monitoring Section

Description

An adsorptive stripping voltametric procedure for direct determination of trace quantities of uranium in sea water has been described. Optimal conditions include pH 6.7, 2 x 10-5M 8-hydroxy quinoline (oxine) and collection potential of -0.4V (Vs Ag/AgCl) at hanging mercury drop electrode. With controlled adsorptive accumulation for one minute a detection limit of 2.8 x 10 -10M uranium is obtained. The response is linear upto 7 x 10 -8M uranium and the relative standard deviation at 4 x 10-9M is 11.5%. The effect of possible interference from other metals has been investigated. (author). 14 refs., 1 tab

Additional details

Publishing Information

Publisher
Bhabha Atomic Research Centre.
Imprint Place
Bombay (India)
Imprint Title
Proceedings of the international symposium on uranium technology [held at Bombay during 13-15 Dec 1989]. V. 1
Imprint Pagination
472 p.
Journal Page Range
v. 1 p. 369-375.
Report number
INIS-mf--13386

Conference

Title
International symposium on uranium technology.
Dates
13-15 Dec 1989.
Place
Bombay (India).