Survey of the Rn dose conversion factor for offices
Creators
Description
The Rn dose conversion factor (DCF), which relates the effective dose to the exposure to the potential α energy concentration (PAEC) of inhaled Rn progeny, was surveyed for 23 occupied and air-conditioned offices in Hong Kong using the bronchial dosimeter for Rn progeny proposed by Yu and Guan in 1998. The mean values of PAEC deposited in the tracheobronchial region (PAECT-B), total PAEC in air (PAECT) and the concentration of Rn (RC) for the offices were 0.13±0.12 mWL, 3.4±3.3 mWL and 30±12 Bq m-3, respectively. An average bronchial deposition fraction of Rn progeny was obtained as 0.037 (range: 0.033-0.051), which gave a DCF of 9.5 (range: 8.4-13) mSv WLM-1. The annual effective dose (E) was estimated to be 0.38±0.35 mSv yr-1 for the offices
Additional details
Identifiers
- PII
- S0265931X00000886;
Publishing Information
- Journal Title
- Journal of Environmental Radioactivity
- Journal Volume
- 51
- Journal Issue
- 3
- Journal Page Range
- p. 379-385
- ISSN
- 0265-931X
- CODEN
- JERAEE
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- Estonia
- INIS RN
- 34063379
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- BRONCHI; CONVERSION; DAUGHTER PRODUCTS; INDOOR AIR CONTAMINATION; OFFICE BUILDINGS; RADIATION DOSES; RADON
- Descriptors DEC
- BUILDINGS; CONTAMINATION; DOSES; ELEMENTS; FLUIDS; GASES; ISOTOPES; NONMETALS; RARE GASES; RESPIRATORY SYSTEM
Optional Information
- Copyright
- Copyright (c) 2000 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.