Research to exploit, utilize computed radiography system and build suitable process

  • 1. Center for Non-Destructive Evaluation, Vietnam Atomic Energy Institute, Hanoi (Viet Nam)

Description

CR is computed radiography method. CR35 is digital radiography equipment which has just equipped in Viet Nam at the end of 2009 by VIE8020 project. The system include image plate (IP) to change for film, CR35 equipment which scans and records IPs signal by laser light and converts to digital image. This system can replaces of film radiography at any where has possible infrastructure like stable power supply, flat, etc. The research purpose is to use the CR35 system, own equipment and technology, compile technical documents and process guide for practice computed radiography. (author)

Part of:
The VINATOM - Annual Report for 2011

Additional details

Publishing Information

Imprint Title
The VINATOM - Annual Report for 2011
Imprint Pagination
334 p.
Journal Page Range
p. 93-97
Report number
VINATOM-AR--11

INIS

Country of Publication
Viet Nam
Country of Input or Organization
Viet Nam
INIS RN
45039866
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Descriptors DEI
AVAILABILITY; COMPUTERIZED TOMOGRAPHY; EQUIPMENT; FILMS; IMAGES; LASERS; PLATES; RESOLUTION; SIGNALS
Descriptors DEC
DIAGNOSTIC TECHNIQUES; TOMOGRAPHY

Optional Information

Notes
18 refs, 4 figs