UV radiation emitted by selected sources at work stands
Description
The paper presents the results of UV effective irradiance measurements at work stands for sources such as: welding arcs, gas blowpipes, exposure processes, printing machines and insecticide lamps. The irradiance measurements were performed using broad-band instruments with detector heads corrected to the Polish action spectra (erythematous and conjunctivitis). The obtained values of effective irradiance for above sources ranged from 0.2 to 8000 mW/m2. Safe exposure time corresponding to irradiance was calculated for the Polish threshold limit values. For welding processes the spectra of selected welding arcs are presented additionally. These spectra were measured using a fiber-optic spectrometer. (author)
Additional details
Publishing Information
- Journal Title
- International Journal of Occupational Medicine and Environmental Health
- Journal Volume
- 14
- Journal Issue
- 3
- Journal Page Range
- p. 287-292
- ISSN
- 1232-1087
INIS
- Country of Publication
- Poland
- Country of Input or Organization
- Poland
- INIS RN
- 36110501
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- HANDS; INSECTICIDES; OCCUPATIONAL EXPOSURE; PAPER INDUSTRY; PERSONNEL; SAFETY; SKIN EFFECT; SPECTROSCOPY; ULTRAVIOLET RADIATION; ULTRAVIOLET SPECTRA; WORKING FACES
- Descriptors DEC
- ARMS; BODY; ELECTROMAGNETIC RADIATION; INDUSTRY; LIMBS; PESTICIDES; RADIATIONS; SPECTRA; WOOD PRODUCTS INDUSTRY
Optional Information
- Notes
- 6 refs, 4 figs, 4 tabs