Check valve slam caused by air intrusion in emergency cooling water system
Description
Waterhammer pressures were experienced during periodic starting of Residual Heat Removal (RHR) pumps at a nuclear plant. Prior to an analytical investigation careful analysis performed by plant engineers indicated that the spring effect of entrapped air in a heat exchanger resulted in water hammer due to check valve slam following flow reversal. In order to determine in more detail the values of pertinent parameters controlling this water hammer a hydraulic transient analysis was performed of the RHR piping system, including essential elements such as the pump, check valve, and heat exchanger. Using characteristic torque and pressure loss curves the motion of the check valve was determined. By comparing output of the water hammer analysis with site recordings of pump discharge pressure the computer model was calibrated, allowing for a realistic estimate of the quantity of entrapped air in the heat exchanger. (author)
Additional details
Publishing Information
- Publisher
- Canadian Nuclear Society
- Imprint Place
- Toronto, Ontario (Canada)
- ISBN
- 978-1-926773-05-6
- Imprint Title
- The 14th International Topical Meeting on Nuclear Reactor Thermalhydraulics (NURETH-14)
- Imprint Pagination
- 766 Megabytes
- Journal Page Range
- [10 p.]
Conference
- Title
- 14. International Topical Meeting on Nuclear Reactor Thermalhydraulics
- Acronym
- NURETH-14
- Dates
- 25-30 Sep 2011
- Place
- Toronto, Ontario (Canada)
INIS
- Country of Publication
- Canada
- Country of Input or Organization
- Canada
- INIS RN
- 47071332
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- AFTER-HEAT REMOVAL; ECCS; HEAT EXCHANGERS; NUCLEAR POWER PLANTS; RELIEF VALVES; WATER HAMMER
- Descriptors DEC
- CONTROL EQUIPMENT; ENGINEERED SAFETY SYSTEMS; EQUIPMENT; FLOW REGULATORS; NUCLEAR FACILITIES; POWER PLANTS; REACTOR PROTECTION SYSTEMS; REMOVAL; THERMAL POWER PLANTS; VALVES
Optional Information
- Notes
- Paper NURETH14-472, 6 refs., 12 figs.