Published 1997 | Version v1
Report

Uranium measurement in urines by ICP-MS. Application to the follow-up of Valduc workers

  • 1. CEA Valduc, 21 - Is-sur-Tille (France)

Description

ICP-MS is a technique with which very high sensitivities (about the ng/L) can be obtained. With this technique it is possible to determine the isotopes weight percentage of a mixture without previous chemical separation while a chemical separation process is necessary for the radiometric analysis methods. This new analysis method offer a possibility to medically follow workers which are exposed to elements whose isotopic composition is different from those of natural mixtures as for instance uranium

Part of:
Analysis: link between physicists, chemists and biologists

Additional details

Additional titles

Original title (French)
Dosage de l'uranium dans les urines par spectrometrie de masse a source plasma. Application au suivi medical du personnel de Valduc

Publishing Information

Imprint Title
Analysis: link between physicists, chemists and biologists
Imprint Pagination
300 p.
Journal Page Range
p. 145-148
Report number
CEA-CETAMA--06-97

Conference

Title
40. anniversary of the CETAMA
Original Conference Title
Journees techniques du 40. anniversaire
Acronym
Technical days
Dates
10-11 Jun 1997
Place
Cadarache (France)

Optional Information

Notes
1 ref. Imprint:L'analyse trait d'union entre les physiciens, les chimistes et les biologistes