Published October 1, 1996 | Version v1
Journal article

Large-area sub-millimeter resolution CdZnTe strip detector for astronomy

  • 1. New Hampshire Univ., Durham (United States). Space Science Center
  • 2. DIGIRAD, San Diego, CA (United States)
  • 3. Louisiana State Univ., Baton Rouge, LA (United States). Dept. of Physics and Astronomy

Description

We report performance measurements of a sub-millimeter resolution CdZnTe strip detector developed as a prototype for astronomical instruments. The prototype is a 1.4 mm thick, 64 x 64 stripe CdZnTe array with 0.375 mm pitch in both dimensions. Pulse height spectra in orthogonal stripe coincidence mode were recorded at several energies. The room-temperature energy resolution is <10 keV (FWHM) for 122 keV photons with a peak-to-valley ratio >5:1. We also demonstrate spatial resolution capabilities finer than the stripe pitch. (orig.)

Additional details

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
380
Journal Issue
1-2
Journal Page Range
p. 490-492.
ISSN
0168-9002
CODEN
NIMAER

Conference

Title
9. international workshop on room temperature semiconductor X- and gamma-ray detectors, associated electronics and applications.
Dates
18-22 Sep 1995.
Place
Grenoble (France).