Experimental study on a hybrid photovoltaic/heat pump system

  • 1. School of Environment and Energy Engineering, Beijing University of Civil Engineering and Architecture, Beijing 100044 (China)
  • 2. Institute of Sustainable Energy Technology, University of Nottingham, University Park, Nottingham NG7 2RD (United Kingdom)

Description

Several studies have found that the decrease of photovoltaic (PV) cell temperature would increase the solar-to-electricity conversion efficiency. Different working fluids such as air and water have been used for the cooling of PV modules, but the improvement in energy performance has been found to be small. In this paper, R134a refrigerant was employed to cool the PV modules. With its low evaporating temperature, it was expected to achieve better cooling effect and electrical performance of the PV modules than using air and water working fluids. An experimental rig of a hybrid micro PV panel-based heat pump system was constructed for the performance testing in a laboratory at University of Nottingham. A small PV panel was made of 6 glass vacuum tube - PV module - aluminium sheet - cooper tube (GPAC) sandwiches connected in series, acting as the evaporator. This was coupled with a small heat pump system. The glass vacuum tubes reduced the heat loss from the PV panel to the ambient, resulting in the improvement of thermal performance. Three testing modes were proposed to investigate the effect of solar radiation, condenser water flow rate and condenser water supply temperature on energy performance. The testing results showed that an averaged COP reached 3.8, 4.3 and 4.0 under the three testing modes with variable radiation, condenser water supply water temperature and water flow rate, respectively, but this could be much higher for a large capacity heat pump system using large PV panels on building roofs. The COP increased with the increasing solar radiation, but decreased with the increasing condenser water supply temperature and water flow rate. The electrical efficiency of PV panel was improved by up to 1.9% based on a reference PV efficiency of 3.9%, compared with that without cooling. The condenser water supply temperature and water flow rate had little effect on the electrical performance. - Highlights: → R134a refrigerant was used for cooling of PV modules. → Performance testing on a hybrid photovoltaic/heat pump system was carried out. → The maximum COP of the hybrid system could reach 6.7. → The electrical efficiency of PV modules was improved by up to 1.9%.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.applthermaleng.2011.08.027

Additional details

Identifiers

DOI
10.1016/j.applthermaleng.2011.08.027;
PII
S1359-4311(11)00457-1;

Publishing Information

Journal Title
Applied Thermal Engineering
Journal Volume
31
Journal Issue
17-18
Journal Page Range
p. 4132-4138
ISSN
1359-4311
CODEN
ATENFT

Conference

Title
9. international conference on sustainable energy technologies
Acronym
SET 2010
Dates
24-27 Aug 2010
Place
Shanghai (China)

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
44087279
Subject category
S42: ENGINEERING;
Resource subtype / Literary indicator
Conference
Descriptors DEI
AIR; COOLING; EFFICIENCY; FLOW RATE; HEAT EXCHANGERS; HEAT LOSSES; HEAT PUMPS; PERFORMANCE TESTING; PHOTOVOLTAIC EFFECT; REFRIGERANTS; SOLAR RADIATION; VAPOR CONDENSERS; WATER; WATER SUPPLY
Descriptors DEC
ENERGY LOSSES; ENERGY TRANSFER; FLUIDS; GASES; HEAT TRANSFER; HYDROGEN COMPOUNDS; LOSSES; OXYGEN COMPOUNDS; PHOTOELECTRIC EFFECT; RADIATIONS; STELLAR RADIATION; TESTING; WORKING FLUIDS

Optional Information

Copyright
Copyright (c) 2011 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.