Published September 1979
| Version v1
Report
Restricted
Code assessment and applications program
Description
A RELAP4/MOD6 Blind Test Prediction of the FLECHT-SEASET Steam Generator Reference Test was made using actual boundary conditions from the test. The code options used were those that had given reasonable results in previous code assessment work with core simulations. Subsequent to the release of the remaining experimental data, further sensitivity calculations were performed. Conclusions concerning the blind prediction and the additional data comparison results are made with reference to the predictive capability of the code. This study was made as part of the INEL support to the NRC for Industry Cooperative Programs
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A04/MF A01.
Files
Additional details
Additional titles
- Augmented title (English)
- PWR
Publishing Information
- Imprint Pagination
- 62 p.
- Report number
- CAAP-TR--057
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 11514334
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- COMPUTER CALCULATIONS; HEAT TRANSFER; HYDRAULICS; MOCKUP; PWR TYPE REACTORS; STEAM GENERATORS
- Descriptors DEC
- BOILERS; ENERGY TRANSFER; REACTORS; STRUCTURAL MODELS; VAPOR GENERATORS; WATER COOLED REACTORS; WATER MODERATED REACTORS