Unavailability of protection and safeguard automatic system on protective action

  • 1. Electricite de France (EDF), 92 - Clamart (France)
  • 2. Electricite de France (EDF), 69 - Lyon (France). Region d'Equipement

Description

For the reliability analysis of redundant systems, we point out the necessity of a system operational modeling, in order to take into account the operating life of the system and the systems interacting with the studied system; this is especially true when redundancy consumption has an effect on interface systems redundancy. Our method uses undistinctly Markov's State Graphs or Petri Networks, coupled with fault trees. Our method is applied to the SPIN system

Part of:
Operability of nuclear systems in normal and adverse environments. Volume 2

Additional details

Publishing Information

Publisher
Societe Francaise d'Energie Nucleaire.
Imprint Place
Paris (France)
Imprint Title
Operability of nuclear systems in normal and adverse environments. Volume 2
Imprint Pagination
422 p.
Journal Page Range
p. 879-886.

Conference

Title
International Conference on Operability of Nuclear Systems in Normal and Adverse Environments.
Dates
18-22 Sep 1989.
Place
Lyon (France).

INIS

Country of Publication
France
Country of Input or Organization
France
INIS RN
21095050
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
MARKOV PROCESS; PWR TYPE REACTORS; REACTOR PROTECTION SYSTEMS; RELIABILITY; SYSTEMS ANALYSIS
Descriptors DEC
ENRICHED URANIUM REACTORS; POWER REACTORS; REACTORS; STOCHASTIC PROCESSES; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS