Effect of increased 99mTc/99Tc ratios on count rates in sentinel node procedures: a randomised study

  • 1. Department of Nuclear Medicine, Medical Centre Alkmaar (Netherlands)
  • 2. Department of Nuclear Medicine, Westfries Gasthuis Hoorn (WFG Hospital Hoorn), P.O. Box 600, 1620 AR, Hoorn (Netherlands)
  • 3. Department of Nuclear Medicine, VUMC Amsterdam (Netherlands)
  • 4. Department of Surgery, Gemini Hospital Den Helder (Netherlands)
  • 5. Department of Surgery, Medical Centre Alkmaar (Netherlands)
  • 6. Department of Surgery, Westfries Hospital Hoorn (Netherlands)

Description

The aim of this study was to evaluate the count rates of sentinel lymph nodes (SLNs) in patients with breast cancer in the operating theatre, using 99mTc-Nanocoll with different ratios of technetium-99m to technetium-99. After written informed consent had been obtained, we tested different ratios of 99mTc/99Tc-Nanocoll in a double-blinded randomised study performed in 161 patients. Twenty-five MBq/μg 99mTc-colloid albumin was prepared in vacuum. In 87 patients (group A) a 2-h elution was used and in 74 patients (group B) a 24-h elution was used. Patients were subcategorised into subgroups 1 and 3, in which an SLN procedure for breast carcinoma was performed simultaneously with lumpectomy, and subgroups 2 and 4, in which an SLN procedure was performed 2-3 weeks after prior excision biopsy. All patients were injected along the lateral border of the areola (two injections: 50 MBq/0.3 ml intradermally and 50 MBq/2 ml intraparenchymally). Ex vivo measurement of count rates was performed with a gamma probe. Comparing groups A and B in respect of registered counts per second (cps) of excised SLNs, a significant difference was found (P<0.004). When comparisons were made between subgroups 1 and 2 (2-h elution) and between subgroups 3 and 4 (24-h elution) in respect of registered cps of excised SLNs, no significant difference was found (subgroup 1 vs 2, P=0.825; subgroup 3 vs 4, P=0.915). Use of a 2-h elution in vacuum yielded a significantly higher count rate of maximum specific activity of 99mTc-colloid albumin in SLNs than was achieved using a 24-h elution in vacuum. SLN procedures performed 2-3 weeks after prior excision biopsy proved reliable as compared to SLN procedures performed simultaneously with lumpectomy. (orig.)

Availability note (English)

Available from: http://dx.doi.org/10.1007/s00259-003-1227-9

Additional details

Identifiers

Publishing Information

Journal Title
European Journal of Nuclear Medicine and Molecular Imaging
Journal Volume
30
Journal Issue
9
Journal Page Range
p. 1231-1235
ISSN
1619-7070