Published December 1982 | Version v1
Report Open

A multi-channel optical beam monitor for the prototype neutral beam injector unit for JT-60

  • 1. Japan Atomic Energy Research Inst., Tokai, Ibaraki. Tokai Research Establishment

Description

A multi-channel optical beam monitor is equipped in the prototype neutral beam injectior unit for jt-60 to measure the beam profile of intense neutral beams. Optical filters are used to eliminate background lights from hot tungsten filamanets in the ion source. The performance test shows that the beam axis is determined within the accuracy of 0.060 for the horizontal direction, and thus the applicability of the optical beam monitor in the JT-60 neutral beam injector. (author)

Availability note (English)

MF available from INIS under the Report Number.

Files

14803810.pdf

Files (794.2 kB)

Name Size Download all
md5:474b1a851c0e3c56db5bec31ecefd452
794.2 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
21 p.
Report number