Published March 2006 | Version v1
Journal article

Classification of events with an off-site radiological impact at the Sellafield site between 1950 and 2000, using the International Nuclear Event Scale

  • 1. Radiation Safety Consultant, 'Brunswick', Cornwall Gardens, Brighton BN1 6RJ (United Kingdom)
  • 2. British Nuclear Fuels plc, 1100 Daresbury Park, Daresbury, Warrington WA4 4GB (United Kingdom)

Description

The paper assesses unplanned operational events at the Sellafield nuclear installation, formerly Windscale and Calder Works, in Cumbria, England, over the period 1950-2000 that had, or could have had, radiological implications for members of the general public. A unified system of off-site impact rating has been developed using a site-specific application of the International Nuclear Event Scale (INES) that is applied retrospectively to events since the start of operations at the site in 1950. Published and unpublished sources of information have been used to assemble what the authors believe to be a complete list of events over the period that would now be assessed as INES level 3 or above on the basis of off-site impact. The last such event occurred in 1984. The exercise also demonstrates that it is possible to apply the current INES rating scheme to a wide variety of radiological events

Availability note (English)

Available online at http://stacks.iop.org/0952-4746/26/33/jrp6_1_002.pdf or at the Web site for the Journal of Radiological Protection (ISSN 1361-6498) http://www.iop.org/

Additional details

Identifiers

Publishing Information

Journal Title
Journal of Radiological Protection
Journal Volume
26
Journal Issue
1
Journal Page Range
p. 33-49
ISSN
0952-4746
CODEN
JRPREA

INIS