Published December 1985 | Version v1
Journal article

Ultrasonography of gallbladder

  • 1. Seoul National University College of Medicine, Seoul (Korea, Republic of)

Description

Ultrasonography has been used in clinical fields because of its merits, such as convenience, non-invasiveness and absence of radiation hazard. With improvement of ultrasonographic technology, diagnostic accuracy is increased in detecting gallstone. Authors performed 41 cases of cholecystosonography and compared with surgical and pathological findings. The results are as follows; 1. Demonstration of gallbladder is accomplished in 40 cases out of 41 cases(97.5%). 2. Gallstone detection rate is 92.5%. False positive rate is 5% and false negative 2.5%. Including one case which turned out C.B.D. stone of false positive detection rate reaches 95%. 3. Diagnostic accuracy of ultrasonography in 17 cases of nonvisualization and faint visualization in oral cholecystogram is 100%. 4. Ultrasonography is essential and highly accurate diagnostic tool in noninvisualized G.B., obstructive jaundice, iodine sensitive and emergency and seriously ill patients.

Additional details

Publishing Information

Journal Title
Journal of the Korean Radiological Society
Journal Volume
15
Journal Issue
2
Series
16 refs, 4 figs
Journal Page Range
p. 504-508
ISSN
1738-2637

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
41027540
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ACCURACY; BILIARY TRACT; DIAGNOSIS; PATHOLOGY; PATIENTS; ULTRASONOGRAPHY
Descriptors DEC
DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM