Published 2008 | Version v1
Journal article

Organ and effective doses of patients arising from coronary angiography and percutaneous transluminal coronary angioplasty at two hospitals in Mashhad-Iran

  • 1. Medical Physics Research Center, Bu Ali Research Inst., Mashad Univ. of Medical Sciences, Mashad (Iran, Islamic Republic of)
  • 2. Medical Physics Dept., Faculty of Medicine, Mashad Univ. of Medical Sciences, Mashad (Iran, Islamic Republic of)

Description

A detailed study of radiation doses received by 83 patients who underwent coronary angiography (CA) and 26 patients who underwent percutaneous transluminal coronary angioplasty (PTCA) by the femoral route in two hospitals in Mashhad-Iran is presented. All procedures were undertaken with Siemens angio-scope X-ray equipment. Thermoluminescent dosimeters (TLD-100), suitably calibrated, were used to measure the dose received at five locations on the patient's skin (on the thyroid, gonads and lens of eyes). A dose area product (DAP) meter was also used. DAP values and fluoroscopy times were recorded for each patient. The mean values for DAP were 32.47 ± 4.03 and 44.49 ± 5.64 Gy cm2 for CA and PTCA, respectively. The patient dosimetry results revealed the thyroid receives the highest dose in CA and PTCA examinations. Also, in this study, DAP to effective dose conversion factors were estimated by means of a Rando phantom and the effective dose received by the patients was estimated for CA and PTCA examinations. The estimated mean values of effective dose were 6.75 ± 0.85 and 9.61 ± 1.24 mSv, respectively. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/ncm366

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
128
Journal Issue
3
Journal Page Range
p. 363-366
ISSN
0144-8420

Optional Information

Notes
11 refs