Published January 21, 2015 | Version v1
Journal article

Absolute prompt-gamma yield measurements for ion beam therapy monitoring

  • 1. CNRS/IN2P3, UMR 5822 F-69622 Villeurbanne (France)
  • 2. Université Lyon 1, F-69622 Villeurbanne (France)
  • 3. IPNL, Université de Lyon, F-69003 Lyon (France)
  • 4. Heidelberg Ion-Beam Therapy Center, Heidelberg (Germany)
  • 5. INSA-Lyon, Centre Léon Bérard (France)
  • 6. INSERM U1044 (France)
  • 7. CNRS UMR 5220 (France)
  • 8. CREATIS, Université de Lyon, F-69003 Lyon (France)
  • 9. GSI Helmholtzzentrum für Schwerionenforschung, Planckstraße 1, 64291, Darmstadt (Germany)
  • 10. Heidelberg University Hospital, Im Neuenheimer Feld 672, 69120 Heidelberg (Germany)
  • 11. Ion Beam Applications SA, Chemin du Cyclotron 3, B-1348 Louvain-la-Neuve (Belgium)

Description

Prompt-gamma emission detection is a promising technique for hadrontherapy monitoring purposes. In this regard, obtaining prompt-gamma yields that can be used to develop monitoring systems based on this principle is of utmost importance since any camera design must cope with the available signal. Herein, a comprehensive study of the data from ten single-slit experiments is presented, five consisting in the irradiation of either PMMA or water targets with lower and higher energy carbon ions, and another five experiments using PMMA targets and proton beams. Analysis techniques such as background subtraction methods, geometrical normalization, and systematic uncertainty estimation were applied to the data in order to obtain absolute prompt-gamma yields in units of prompt-gamma counts per incident ion, unit of field of view, and unit of solid angle. At the entrance of a PMMA target, where the contribution of secondary nuclear reactions is negligible, prompt-gamma counts per incident ion, per millimetre and per steradian equal to (124 ± 0.7stat ± 30sys) × 10−6 for 95 MeV u−1 carbon ions, (79 ± 2stat ± 23sys) × 10−6 for 310 MeV u−1 carbon ions, and (16 ± 0.07stat ± 1sys) × 10−6 for 160 MeV protons were found for prompt gammas with energies higher than 1 MeV. This shows a factor 5 between the yields of two different ions species with the same range in water (160 MeV protons and 310 MeV u−1 carbon ions). The target composition was also found to influence the prompt-gamma yield since, for 300/310 MeV u−1 carbon ions, a 42% greater yield ((112 ± 1stat ± 22sys) × 10−6 counts ion−1 mm−1 sr−1) was obtained with a water target compared to a PMMA one. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/0031-9155/60/2/565

Additional details

Identifiers

Publishing Information

Journal Title
Physics in Medicine and Biology
Journal Volume
60
Journal Issue
2
Journal Page Range
p. 565-594
ISSN
0031-9155
CODEN
PHMBA7

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
47004754
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
CAMERAS; CARBON IONS; EMISSION; ION BEAMS; IRRADIATION; MONITORING; PMMA; PROTON BEAMS; RADIOTHERAPY; SIGNALS; WATER
Descriptors DEC
BEAMS; CHARGED PARTICLES; ESTERS; HYDROGEN COMPOUNDS; IONS; MEDICINE; NUCLEAR MEDICINE; NUCLEON BEAMS; ORGANIC COMPOUNDS; ORGANIC POLYMERS; OXYGEN COMPOUNDS; PARTICLE BEAMS; POLYACRYLATES; POLYMERS; POLYVINYLS; RADIOLOGY; THERAPY