Quality Control of Individual Radioprotection Equipment: Methodology and Organization in the University Hospitals of Geneva
- 1. Medical and Quality Management Department, University Hospitals of Geneva (Switzerland)
- 2. Radiology Department, University Hospitals of Geneva (Switzerland)
Description
In 2018 the new Radioprotection Ordinance in Switzerland came into forced requiring the radiation protection equipment to be checked annually for its proper performance. Indeed, to provide safe operating conditions for staff working with ionizing radiation, the personal protective equipment (PPE) (protective aprons, skirts, jackets, goggles and thyroid shields) should be checked at least once a year. It is up to the radiation protection expert to make an inventory of the existing radiation protection equipment in the institution and to setup a quality control procedure to ensure its performance. A lot of work has been done with the hospital's internal equipment management database system (EMDS) to identify and include the protective equipment in the follow up system. Moreover, a quality control procedure has been established considering the most logical and optimized method inside the Institution. We present here the preliminary results. Materials and methods: self-adhesive labels were used to identify all 670 radiation protective equipment and the information gathered into the EMDS. Once identified, the aprons, skirts, jackets and protective thyroid shields were tested using different methods: first visually (tear in the outer layer, defects at the fasteners) then tactilely (suspicious mass, internal tear, tear at the fasteners/seams) (fig. a, b, c and d) and at the end radiographically. For this last method, several options were considered but the EOS® system was chosen since it provides 2 acquisitions at the same time front/profile (fig. e, f, g, h, i and j) in vertical position (wearing position) and without further exposure of the staff. A score, established according to the location of the detected defects (fig. k) is provided and the results qualifies the equipment as: 0-2 -> OK; 3-5: to be withdraw in the coming months (until new replacement equipment arrives); larger than 5: waste.
Additional details
Identifiers
Publishing Information
- Imprint Title
- International Conference on Occupational Radiation Protection #En Dash# Strengthening Radiation Protection of Workers #En Dash# Twenty Years of Progress and the Way Forward. Abstracts and Posters
- Imprint Pagination
- 249 p.
- Journal Page Range
- p. 177
- Report number
- IAEA-CN--300
Conference
- Title
- International Conference on Occupational Radiation Protection - Strengthening Radiation Protection of Workers - Twenty Years of Progress and the Way Forward
- Dates
- 5-9 Sep 2022
- Place
- Geneva (Switzerland)
INIS
- Country of Publication
- International Atomic Energy Agency (IAEA)
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 54049438
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- EDUCATIONAL FACILITIES; HOSPITALS; IONIZING RADIATIONS; OCCUPATIONAL EXPOSURE; OCCUPATIONAL SAFETY; QUALITY CONTROL; RADIATION PROTECTION; SHIELDS; SWITZERLAND; THYROID
- Descriptors DEC
- BODY; BUILDINGS; CONTROL; DEVELOPED COUNTRIES; ENDOCRINE GLANDS; EUROPE; GLANDS; MEDICAL ESTABLISHMENTS; ORGANS; RADIATIONS; SAFETY; WESTERN EUROPE
Optional Information
- Secondary number(s)
- IAEA-CN--300-188