Published October 2002 | Version v1
Journal article

Relativistic electron beams detection in a dense plasma focus

  • 1. Universidad Nacional del Centro de la Provincia de Buenos Aires, Instituto de Fisica Arroyo Seco, Tandil (Argentina)
  • 2. Universidad Nacional del Mar del Plata, Dept. de Fisica, Facultad de Ciencias Exactas y Naturales, Mar del Plata (Argentina)

Description

Fast electron beams into a hollow anode of a small plasma focus machine (2 kJ, 4 μF) were measured. The diagnostic method designed for this purpose is founded in a small Rogowski coil introduced into a cavity performed in the anode. By means of this, electron beam pulses of about 10 ns width generated in the plasma focus are detected. Simultaneously, hard X-ray signals obtained from a scintillator-photomultiplier system are registered. The electron beam energy was measured through the time-of-flight of the electrons between probe and anode top. The beams are found to be relativistic and its energy is into the range of hard X-rays energy. An analysis of signal intensities and relative delays for three hundred shots are here presented. (authors)

Additional details

Publishing Information

Journal Title
European Physical Journal. D, Atomic, Molecular and Optical Physics
Journal Volume
21
Journal Issue
no.1
Journal Page Range
p. 97-100
ISSN
1434-6060

Optional Information

Notes
19 refs.