Published July 1996 | Version v1
Journal article

Radiation dose by spiral CT and conventional tomography of the sternoclavicular joints and the manubrium sterni

  • 1. Department of Diagnostic Radiology R, Aarhus Kommunehospital, Noerrebrogade 44, DK-8000 Aarhus C (Denmark)
  • 2. Department of Medical Physics, Aarhus Kommunehospital, Aarhus (Denmark)

Description

Objective, design and patients. Conventional frontal tomography of the sternum has to some extent been replaced by spiral computed tomography (CT). The objective of this study was to analyse this change of procedure in terms of dosimetry by measurement of the radiation dose to individual organs using an anthropomorphic Rando Alderson phantom. Results. The total effective radiation dose in examination of the sternoclavicular joints and the manubrium sterni was found to be lower using spiral CT than conventional tomography, the values being 0.6 and 0.8 mSv, respectively. Conclusion. As spiral CT is diagnostically comparable and in some respects superior to tomography, its use is recommended for studies of the sternum. (orig.). With 4 tabs

Additional details

Publishing Information

Journal Title
Skeletal Radiology
Journal Volume
25
Journal Issue
5
Journal Page Range
p. 467-470.
ISSN
0364-2348
CODEN
SKRADI

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
27065615
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
CHEST; COMPUTERIZED TOMOGRAPHY; DOSIMETRY; PHANTOMS; RADIATION DOSES; RADIATION PROTECTION; SKELETON
Descriptors DEC
BODY; BODY AREAS; MOCKUP; ORGANS; STRUCTURAL MODELS; TOMOGRAPHY