Published April 2007 | Version v1
Book

MELCOR analysis of helium/water/air ingress into ITER cryostat and vacuum vessel

  • 1. Studsvik Nuclear AB, SE-611 82 Nykoeping (Sweden)

Description

This accident is postulated starting with two large holes respectively on vacuum vessel and cryostat simultaneously with water and helium cooling pipe breaks. One base case, eight parameter studies and one 'very conservative case' are studied by MELCOR. The analysis results showed that the cryostat and vacuum vessel pressures for this accident remain below the design limits of 200 kPa. The consequential radioactive releases of tritium and W dust stay well below the no-evacuation limits, which are 90 g of tritium and 16 kg of W dust. (author)

Part of:
Fusion power plant safety. Proceedings of a technical meeting

Additional details

Publishing Information

Publisher
IAEA
Imprint Place
Vienna (Austria)
ISBN
92-0-102007-4
Imprint Title
Fusion power plant safety. Proceedings of a technical meeting
Imprint Pagination
960 p.
Series
Proceedings CD series
Journal Page Range
[7 p.]
ISSN
1991-2374

Conference

Title
8. technical meeting on fusion power plant safety
Dates
10-13 Jul 2006
Place
Vienna (Austria)

Optional Information

Notes
3 refs, 4 figs, 2 tabs; Paper, presentation and synopses are available
Secondary number(s)
OT--02