Daily interactive use of portal imaging for monitoring thoracic cancer radiotherapy
Creators
- 1. Hopital Pitie-Salpetriere, 75 - Paris (France)
- 2. Centre Oscar-Lambert, 59 - Lille (France)
Description
A Siemens electronic portal imaging system called BeamviewplusTM was used daily in 15 lung cancer patients for each X-ray field. Out of the 714 expected portal images, 585 (82%), were obtained and printed. We counted 94 errors in the 585 successful controls (16 %). Four main classes of errors were identified: irradiation field placement (47 cases, 50 %), shielding placement (30 cases, 32 %), patients's position on the tilt examining table (14 cases, 15 %), and selection of the energy (3 cases, (3 %). Forty percent of these errors were potentially serious in terms of treatment volume and vital organ protection. Only portal imaging control could easily detect errors because they occurred randomly. We thus consider the use of this daily system helpful for patient management. (author)
Additional details
Additional titles
- Original title (French)
- Utilisation d'un systeme d'imagerie en temps reel dans le controle quotidien de patients traites par irradiation pour un cancer thoracique
Publishing Information
- Journal Title
- Cancer Radiotherapie
- Journal Volume
- 1
- Journal Issue
- no.3
- Series
- 30 refs.
- Journal Page Range
- p. 249-257
- ISSN
- 1278-3218
- CODEN
- CARAFC
INIS
- Country of Publication
- France
- Country of Input or Organization
- France
- INIS RN
- 29041851
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- CARCINOMAS; CHEST; IMAGES; NUCLEAR MEDICINE; PORTAL SYSTEM; QUALITY ASSURANCE; RADIOTHERAPY
- Descriptors DEC
- BLOOD VESSELS; BODY; BODY AREAS; CARDIOVASCULAR SYSTEM; DISEASES; MEDICINE; NEOPLASMS; ORGANS; THERAPY; VEINS