Long-term clearance of accidentally inhaled 60Co aerosols in humans

  • 1. Hungarian Academy of Sciences, Budapest (Hungary). Central Research Inst. for Physics
  • 2. Magyar Tudomanyos Akademia, Budapest (Hungary). Izotopintezete

Description

Long-term body retention was measured on six workers inhaling 60Co aerosols incidentally during manipulation with a high activity 60Co source. An improved whole body counter technique and calibration provided good conditions to follow the body clearance over 4 years. A two-detector profile scanning arrangement was used to measure the activity distribution 'in vivo' over the lung region. The observed whole body retention followed a two-exponential time function between 10-1500 days. The consistency of the measured retention pattern with ICRP inhalation model was investigated assuming different aerosol size distributions. A possible extension of ICRP lung model is proposed to take into account the actual pulmonary lung clearance determined individually. (R.P.) 29 refs.; 15 figs.; 6 tabs

Availability note (English)

MF available from INIS under the Report Number.

Files

25000487.pdf

Files (940.6 kB)

Name Size Download all
md5:4d5282a0e2a23f86fc6cc45886e814b5
940.6 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
42 p.
Report number
KFKI--1992-36/K