Published November 1986
| Version v1
Journal article
Measurements of peak field grandient of pulsed quadrupole magnets
Creators
- 1. Academia Sinica, Beijing (China). Inst. of High Energy Physics
Description
A measuring method of peak field grandient of pulsed quadrupole magnets is described. A pair of coils for grandient, an integrater and measuring circuit of peak voltage are used in this measurements. It is used for field measurements of drift tube quadrupole magnets in proton Linac. It's accuracy is 0.3%. The excitation curves of two of drift tube quadrupole magnets are given and compared with theory
Additional details
Publishing Information
- Journal Title
- At. Energy Sci. Technol.
- Journal Volume
- 20
- Journal Issue
- 6
- Series
- At. Energy Sci. Technol.
- Journal Page Range
- 742-745
- CODEN
- YKJIE
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 18100119
- Subject category
- S43: PARTICLE ACCELERATORS;
- Descriptors DEI
- DRIFT TUBES; ELECTRIC COILS; LENSES; LINEAR ACCELERATORS; MAGNETIC FIELDS; MAGNETS; MEASURING METHODS; PROTONS; PULSES; QUADRUPOLES
- Descriptors DEC
- ACCELERATORS; BARYONS; CATIONS; CHARGED PARTICLES; ELECTRICAL EQUIPMENT; ELEMENTARY PARTICLES; EQUIPMENT; FERMIONS; HADRONS; HYDROGEN IONS; HYDROGEN IONS 1 PLUS; IONS; MULTIPOLES; NUCLEONS