Tritium removal: a preliminary evaluation of several getters

Description

The removal of hydrogen isotopes from flowing gas streams is an important aspect of CTR technology for both decontamination and tritium recovery from plasma exhausts. Several getters have been evaluated for their tritium scrubbing potential at the parts per billion level. Measurements of total capacity and dynamic response have been made for barium, erbium, palladium dispersed on molecular sieve, General Electric H-36 (zirconium alloy), Union Carbide Y-993 (PdMnO2), Societa Apparecchi Electtrici e Scientifici Getters ST101 (Zr--Al), ST171, and ST181, and a Sandia developed organic material, dimerized phenyl propargyl ether (DPPE). Preliminary flow studies were conducted by passing mixtures of either hydrogen or deuterium diluted with argon through packed beds containing the getter and periodically sampling the effluent with a gas chromatograph sensitive to 500 ppB H2. The results of this work, similar flow experiments using tritium and total capacity measurements are presented in the text

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS.