Published October 1995
| Version v1
Report
Open
Beam position dependence of a wall-current monitor
- 1. Naruto Univ. of Education, Tokushima (Japan)
Description
It was pointed out recently that there exists an appreciable beam position dependence in the wall-current monitor widely used in electron accelerators. Detailed study of this dependence is performed on a test bench varying the pulse width and the frequency of the input signal simulating the beam. The results of experiments show that when the pulse width becomes shorter more appreciable becomes the dependence, and it approaches to that of calculated from the method of images. A unified analysis is under way. (author)
Files
27044962.pdf
Files
(150.6 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:de50ce37135a7d2ac961dec31dee50b2
|
150.6 kB | Preview Download |
Additional details
Publishing Information
- Imprint Title
- Proceedings of the 10th symposium on accelerator science and technology
- Imprint Pagination
- 490 p.
- Journal Page Range
- p. 257-259.
- Report number
- JAERI-Conf--95-021
Conference
- Title
- 10. symposium on accelerator science and technology.
- Dates
- 25-27 Oct 1995.
- Place
- Hitachinaka, Ibaraki (Japan).
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 27044962
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BEAM MONITORS; BEAM POSITION; BENCH-SCALE EXPERIMENTS; DRIFT TUBES; ELECTRIC CONDUCTORS; ELECTRIC CURRENTS; ELECTRON BEAMS; SENSITIVITY; SIMULATION; WALLS
- Descriptors DEC
- BEAMS; CURRENTS; LEPTON BEAMS; MEASURING INSTRUMENTS; MONITORS; PARTICLE BEAMS