Published 1987 | Version v1
Book

Lessons learned from a review of post-accident sampling systems, high range effluent monitors and high concentration particulate iodine samplers

  • 1. Safety and Environmental Protection Div., Brookhaven National Lab., Upton, NY (USA)
  • 2. Knox Consultants, 4794 Springfield Drive, Dunwoody, GA (USA)
  • 3. USNRC Region I, 631 Park Avenue, King of Prussia, PA (USA)

Description

Post-accident sampling systems (PASS), high range gaseous effluent monitors and sampling systems for particulates and iodine in high concentrations which were installed to meet the requirements of NUREG-0737 have been reviewed at twenty-one licensee sites in Region I of the U.S. Nuclear Regulatory Commission which includes fifteen BWR's and fourteen PWR's. Although most of the installed PASS met the NUREG-0737 criteria, the highest operational readiness was found in on-line systems which were also used for routine sampling and analysis. The detectors used in the gaseous effluent monitors included external ion chambers, GM tubes, organic scintillators and Cd-Te solid state crystals. Although all were found acceptable, each had its own inherent limitations in the conversion of detector output to the time varying concentration of a post-accident mixture of noble gases

Additional details

Publishing Information

Publisher
Health Physics Society.
Imprint Place
McLean, VA (USA)
Imprint Title
Proceedings of the twentyfirst midyear topical meeting of the Health Physics Society
Imprint Pagination
vp.
Journal Page Range
p. 19-34.

Conference

Title
power reactor health physics.
Acronym
21. mid-year topical meeting of the Health Physics Society
Dates
13-17 Dec 1987.
Place
Bel Harbour, FL (USA).

Optional Information

Secondary number(s)
CONF-871202--.