Air quality evaluation in the area around the Jorge Lacerda Thermoelectric Complex in Santa Catarina State, Brazil: 1987 to 1991 period

  • 1. Centrais Eletricas do Sul do Brasil S.A. (ELETROSUL), Florianopolis, SC (Brazil)

Description

This report presents the results of the Air Quality Monitoring Program carried out by ELETROSUL in the period of 1987 to 1991, in the influence area of the Jorge Lacerda Thermoelectric Complex, in Santa Catarina State, Brazil. The results show that for sulfur dioxide the air quality was good for 95% of the measurements, while for the total suspended particulates the corresponding value was 80%. 9 refs., 3 figs., 1 tab

Availability note (English)

Available from the Nuclear Information Center of Brazilian Nuclear Energy Commission, Rio de Janeiro.

Additional details

Additional titles

Original title (Portuguese)
Avaliacao da qualidade do ar na area de influencia do Complexo Termeletrico Jorge Lacerda: periodo 1987 a 1991

Publishing Information

Imprint Pagination
6 p.

Conference

Title
12. National seminar on production and transmission of electric power.
Original Conference Title
12. SNPTEE: Seminario nacional de producao e transmissao de energia eletrica
Dates
3-7 Oct 1993.
Place
Recife, PE (Brazil).