Published March 1993 | Version v1
Miscellaneous

Overview of recent results from the Tore Supra ECE diagnostics

  • 1. Association EURATOM-CEA sur la Fusion, Centre d'Etudes de Cadarache, 13 - St. Paul-lez-Durance (France)

Description

The Tore Supra ECE diagnostic system consists of a set of 3 Michelson and 12 Fabry-Perot interferometers, which is now fully operational. We present results obtained with the 3 Michelson during LHCD experiments first. It is shown how the sensitivity of the diagnostic to rather high v perpendicularto prevents detection of v parallel anisotropies. On the other hand, measurements during the Ohmic phase reveal some unexpected anisotropy which can be attributed to superthermal electrons related to the bootstrap current. The 12 Fabry-Perot have been operated using high acquisition sampling rates during pellet injection experiments. A shudder preceding the pellet itself is clearly evidenced just before an internal disruption occurs. During sawtooth activity, such measurements are also used to study the dynamics of the m=1, n=1 instability on the q=1 surface itself. (orig.)

Part of:
Proceedings of eighth joint workshop on electron cyclotron emission and electron cyclotron resonance heating. Vol. 1

Additional details

Publishing Information

Imprint Title
Proceedings of eighth joint workshop on electron cyclotron emission and electron cyclotron resonance heating. Vol. 1
Imprint Pagination
318 p.
Journal Page Range
p. 291-304.
Report number
IPP--III/186(v.1)

Conference

Title
8. joint workshop on electron cyclotron emission and electron cyclotron resonance heating.
Dates
19-21 Oct 1992.
Place
Ising (Germany).

Optional Information