Published October 2010 | Version v1
Journal article

Performance of Diagnostic Neutral Beam for the HT-7 Tokamak

  • 1. Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China)

Description

Diagnostic neutral beam (DNB), combined with spectral diagnostics, is employed to measure the ion temperature in HT-7. The factors affecting the extracted beam are studied in the experiment for the high performance diagnostic neutral beam. A 6.5 A extracted hydrogen current at 43 keV of 100 ms was obtained after optimization. The extracted beam has a proton ratio as high as 40%, and can penetrate into the core plasma after neutralization to measure the ion temperature effectively.

Availability note (English)

Available from http://dx.doi.org/10.1088/1009-0630/12/5/06

Additional details

Identifiers

Publishing Information

Journal Title
Plasma Science and Technology
Journal Volume
12
Journal Issue
5
Journal Page Range
p. 540-542
ISSN
1009-0630

INIS

Country of Publication
China
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
42024972
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Descriptors DEI
BEAMS; HT-7 TOKAMAK; ION TEMPERATURE; PERFORMANCE; PLASMA DIAGNOSTICS
Descriptors DEC
CLOSED PLASMA DEVICES; THERMONUCLEAR DEVICES; TOKAMAK DEVICES