Former studies by Hoeschen and Buhr indicated a higher total noise in a thorax image than expected from technical noise, i.e. quantum and detector noise. This difference results from the overlay of many small anatomical structures along the X-ray beam, which leads to a noise-like appearance without distinguishable structures in the projected image. A method is proposed to quantitatively determine this 'anatomical noise' component, which is not to be confused with the anatomical background (e.g. ribs). This specific anatomical noise pattern in a radiograph changes completely when the imaging geometry changes because different small anatomical structures contribute to the projected image. Therefore, two images are taken using slightly different exposure geometry, and a correlation analysis based on wavelet transforms allows to determining the uncorrelated noise components. Since the technical noise also differs from image to image, which makes it difficult to separate the anatomical noise, images of a lung phantom were produced on a low-sensitive industrial X-ray film using high-exposure levels. From these results, the anatomical noise level in real clinical thorax radiographs using realistic exposure levels is predicted using the general dose dependence described in the paper text and compared with the quantum and detector noise level of an indirect flat-panel detector system. For consistency testing, the same lung phantom was imaged with the same digital flat-panel detector and the total image noise including anatomical noise is determined. The results show that the relative portion of anatomical noise may exceed the technical noise level. Anatomical noise is an important contributor to the total image noise and, therefore, impedes the recognition of anatomical structures. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/nch543

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
114
Journal Issue
1-3
Journal Page Range
p. 75-80
ISSN
0144-8420

Conference

Title
2. Malmoe Conference on Medical X-Ray Imaging - Optimisation strategies in medical X-ray imaging
Dates
23-25 Apr 2004
Place
Malmoe (Sweden)

INIS

Country of Publication
United Kingdom
Country of Input or Organization
France
INIS RN
44035769
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BEAMS; CHEST; COMPARATIVE EVALUATIONS; FILMS; IMAGE PROCESSING; IMAGES; LUNGS; NOISE; PHANTOMS; RADIATION DOSES; TESTING; X RADIATION
Descriptors DEC
BODY; DOSES; ELECTROMAGNETIC RADIATION; EVALUATION; IONIZING RADIATIONS; MOCKUP; ORGANS; PROCESSING; RADIATIONS; RESPIRATORY SYSTEM; STRUCTURAL MODELS

Optional Information

Notes
15 refs