Published 1985 | Version v1
Journal article

Heat extraction from turbines of Czechoslovak nuclear power plants for district heating

Creators

  • 1. Skoda, Plzen (Czechoslovakia). Zavod Energeticke Strojirenstvi

Description

Two design are described of SKODA extraction turbines for Czechoslovak nuclear power plants with WWER-440 and WWER-1000 reactors. 220 MW steam turbines were originally designed as pure condensation turbines with uncontrolled steam extraction. Optimal ways are now being sought for their use for heating hot water for district heating. For district heating of the town of Trnava, the nuclear power plant at Jaslovske Bohunice will provide a two-step heating of water from 70 to 120 degC with a heat supply of 60 MWth from one turbine unit. The ratio of obtained heat power to lost electric power is 5.08. Investigations showed the possibility of extracting 85 MWth of heat from uncontrolled steam extraction, this at three-step water heating from 60 to 145 degC, the ratio of gained and lost power being 7.14. Information is presented on the SKODA 220 MW turbine with steam extraction for heat supply purposes and on the 1000 MW turbine with 893 MWth heat extraction. The specifications of both types are given. (Pu)

Additional details

Additional titles

Original title (Czech)
Odber tepla z turbin v jadernych elektrarnach v CSSR pro centralizovane zasobovani teplem

Publishing Information

Journal Title
Teplo
Journal Volume
4
Journal Issue
1
Series
Teplo.
Journal Page Range
8-11
CODEN
TEPLE