Published 2010 | Version v1
Miscellaneous Open

Rapid proto typing of dental prosthesis by means of a feldspathic glass composite mixed with muscovite mica via CAD/CAM

Description

The work consists in the use and integration of CAD/CAM tools as a process of design and manufacture of a rapid prototyping of dental prosthesis by machining using a CNC milling machine. The material machined to obtain the dental prosthesis were cylindrical blocks of a Feldspathic glass composite mixed with muscovite mica in various percentages (15%, 40% and 80%), which was resigned under biaxial pressing and sintered in vacuum at temperatures from 800 to 1100 deg C. The composite was characterized by XRD and SEM. The results show that increasing the crystallization of leucite is consequent to the temperature increase, and that the use of CAD/CAM system using a CNC milling machine is feasible to obtain dental prosthesis. (author)

Files

42046200.pdf

Files (2.5 MB)

Name Size Download all
md5:b97a6b2c9958e8cbd811f7b8a8f6685f
2.5 MB Preview Download

Additional details

Additional titles

Original title (Portuguese)
Prototipagem rapida de proteses dentarias por meio de um composito de vidro feldspatico misturado com mica moscovita via CAD/CAM

Publishing Information

Imprint Pagination
8 p.
Report number
INIS-BR--9047

Conference

Title
Brazilian congress on engineering and materials science
Original Conference Title
19. CBECIMAT: Congresso brasileiro de engenharia e ciencia dos materiais
Acronym
19. CBECIMAT
Dates
21-25 Nov 2010
Place
Campos do Jordao, SP (Brazil)

Optional Information

Notes
Code: 209-002.pdf