The magnet support system for the SLC Arcs will be a long series of pedestals with each pedestal supporting the ends of two adjacent magnets. It has been pointed out by several authors that random magnet vibrations in the Arc with amplitudes larger than 0.1 μm rms are potentially harmful for the SLC operation. In order to assess the vibrational behavior of the Arc magnet system, we need to understand: (1) the sources and characteristics of the ground disturbances, (2) the coupled vibrational modes of the composite pedestal-magnet system, and (3) the response of the system to ground disturbance. This note is an attempt to study item (2). 5 refs., 4 figs., 1 tab

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01; 1 as DE85014288.

Files

17006791.pdf

Files (172.7 kB)

Name Size Download all
md5:0dc2ce067220992799def6078dbfcdbb
172.7 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
4 p.
Report number
SLAC-PUB--3607

Conference

Title
Particle accelerator conference.
Dates
13-16 May 1985.
Place
Vancouver, British Columbia (Canada).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
17006791
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ALIGNMENT; BEAM BENDING MAGNETS; MECHANICAL VIBRATIONS; RESONANCE; STANFORD LINEAR COLLIDER
Descriptors DEC
ACCELERATORS; EQUIPMENT; LINEAR ACCELERATORS; MAGNETS

Optional Information

Secondary number(s)
CONF-850504--198.