Published December 20, 1990 | Version v1
Journal article

Computed tomography of radioactive objects and materials

  • 1. Atomic Energy of Canada Ltd., Chalk River, ON (Canada). Chalk River Nuclear Labs.

Description

Computed tomography (CT) has been performed on a number of radioactive objects and materials. Several unique technical problems are associated with CT of radioactive specimens. These include general safety considerations, techniques to reduce background-radiation effects on CT images and selection criteria for the CT source to permit object penetration and to reveal accurate values of material density. In the present paper, three groups of experiments will be described, for objects with low, medium and high levels of radioactivity. CT studies on radioactive specimens will be presented. They include the following: (1) examination of individual ceramic reactor-fuel (uranium dioxide) pellets, (2) examination of fuel samples from the Three Mile Island reactor, (3) examination of a CANDU (CANada Deuterium Uranium: registered trademark) nuclear-fuel bundle which underwent a simulated loss-of-coolant accident resulting in high-temperature damage and (4) examination of a PWR nuclear-reactor fuel assembly. (orig.)

Additional details

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research, Section A
Journal Volume
299
Journal Issue
1-3
Series
Nucl. Instrum. Methods Phys. Res., Sect. A.
Journal Page Range
468-479
ISSN
0168-9002
CODEN
NIMAE

Conference

Title
Radiation measurements and applications.
Acronym
7. symposium on X-ray and gamma-ray sources and applications
Dates
21-24 May 1990.
Place
Ann Arbor, MI (USA).