A Monte Carlo method and finite volume method coupled optical simulation method for parabolic trough solar collectors

  • 1. Key Laboratory of Efficient Utilization of Low and Medium Grade Energy (Tianjin University), Ministry of Education of China, Tianjin 300350 (China)
  • 2. School of Environmental Science and Engineering, Tianjin University, Tianjin 300350 (China)

Description

Highlights: •Four optical models for parabolic trough solar collectors were compared in detail. •Characteristics of Monte Carlo Method and Finite Volume Method were discussed. •A novel method was presented combining advantages of different models. •The method was suited to optical analysis of collectors with different geometries. •A new kind of cavity receiver was simulated depending on the novel method. -- Abstract: The PTC (parabolic trough solar collector) is widely used for space heating, heat-driven refrigeration, solar power, etc. The concentrated solar radiation is the only energy source for a PTC, thus its optical performance significantly affects the collector efficiency. In this study, four different optical models were constructed, validated and compared in detail. On this basis, a novel coupled method was presented by combining advantages of these models, which was suited to carry out a mass of optical simulations of collectors with different geometrical parameters rapidly and accurately. Based on these simulation results, the optimal configuration of a collector with highest efficiency can be determined. Thus, this method was useful for collector optimization and design. In the four models, MCM (Monte Carlo Method) and FVM (Finite Volume Method) were used to initialize photons distribution, as well as CPEM (Change Photon Energy Method) and MCM were adopted to describe the process of reflecting, transmitting and absorbing. For simulating reflection, transmission and absorption, CPEM was more efficient than MCM, so it was utilized in the coupled method. For photons distribution initialization, FVM saved running time and computation effort, whereas it needed suitable grid configuration. MCM only required a total number of rays for simulation, whereas it needed higher computing cost and its results fluctuated in multiple runs. In the novel coupled method, the grid configuration for FVM was optimized according to the "true values" from MCM of collectors with the maximum geometry difference. Following this, the initialization of photons distribution of collectors with different geometries were conducted with FVM. To demonstrate this coupled model in real practice, performance analysis of a kind of cavity receiver for PTCs was carried out. The judgment of collectors with maximum geometry difference were worth investigating further in the future work.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.apenergy.2017.05.047

Additional details

Identifiers

DOI
10.1016/j.apenergy.2017.05.047;
PII
S0306-2619(17)30549-4;

Publishing Information

Journal Title
Applied Energy
Journal Volume
201
Journal Issue
Complete
Journal Page Range
p. 60-68
ISSN
0306-2619
CODEN
APENDX

Optional Information

Copyright
Copyright (c) 2017 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.