Published March 1995 | Version v1
Report Open

Preliminary 2D design study for A ampersand PCT

Description

Lawrence Livermore National Laboratory is currently designing and constructing a tomographic scanner to obtain the most accurate possible assays of radioactivity in barrels of nuclear waste in a limited amount of time. This study demonstrates a method to explore different designs using laboratory experiments and numerical simulations. In particular, we examine the trade-off between spatial resolution and signal-to-noise. The simulations are conducted in two dimensions as a preliminary study for three dimensional imaging. We find that the optimal design is entirely dependent on the expected source sizes and activities. For nuclear waste barrels, preliminary results indicate that collimators with widths of 1 to 3 inch and aspect ratios of 5:1 to 10:1 should perform well. This type of study will be repeated in 3D in more detail to optimize the final design

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE96000353; NTIS; US Govt. Printing Office Dep.

Files

27020075.pdf

Files (483.0 kB)

Name Size Download all
md5:37bf21229a0f8d1f4688bc98c5d6eff7
483.0 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
16 p.
Report number
UCRL-ID--120523

Optional Information

Contract/Grant/Project number
Contract W-7405-ENG-48
Funding organization
USDOE, Washington, DC (United States).