Published June 1999 | Version v1
Journal article

Experience from using plastic film in radon measurement

Creators

Description

Plastic film is a useful detector of radon gas. The method of detection of the gas is used for several decades to measure radon concentrations both indoors and in soil. Experiences from radon measurements in Sweden indoors, in soil and in water using the plastic film Kodak LR 115-II are discussed in this report. Some examples are given from various projects. One example is taken from a large scale mapping of indoor radon levels in houses, where the building material is the main source of radon. In another example the measurements from a large scale soil radon mapping are discussed. The use of the plastic film for measurements of radon levels in water is also discussed. All the investigations are made in order to give the authorities concerned information of the radon situation and to study the connection between high indoor radon levels and various types of cancers

Additional details

Identifiers

PII
S1350448799001018;

Publishing Information

Journal Title
Radiation Measurements
Journal Volume
31
Journal Issue
1-6
Journal Page Range
p. 265-270
ISSN
1350-4487
CODEN
RMEAEP

Optional Information

Copyright
Copyright (c) 1999 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.