Optimizing radiation dose for thorax CT scan with bolus triggering activation delay setting (study at the radiology installation at DR Moewardi hospital)

  • 1. Health Polytechnics of Semarang-Indonesia (Indonesia)
  • 2. Radiologist Technologist in Moewardi Hospital (Indonesia)

Description

Thorax CT examination in dr. Moewardi Hospital Surakarta is performed by bolus triggering technique. Bolus trigering activation delay is adjusted at 5 to10 second after contrast injection by automatic injector. Radiation dose can be minimize by using this technique, but inapropriate delay adjustment can reduce the image accuracy. Contrast media enhancement of region of interest can be missed due to very long activation delay. This reseach aims to find out the effect of activation delay of bolus trigerring toward the radiation dose and to determine its possible maximum value. This is experimental research. Eight patients were divided into eight groups by random group design. Eight variations of activation delay (0, 2, 4, 6, 8, 10, 12, and 14) were applied to the groups. The dose (CTDIvol) for every scan was calculated by the scanner system and displayed directly on the monitor. Data were analyzed using regression statistic. This research method has been reviewed and aproved by The Ethic Comittee of Health Polytechnic of Semarang. The result showed that there was very strong effect of the bolus triggering activation delay toward the radiation dose (r = 0,97) (p-value <0,001) and determination coeficient (R2) = 0,940. The radiation dose was affected 94% by the activation delay. The equation of Y = 308,252 - 18,821Time Delay indicated that there was 18,821 mGy dose reduction for 1 second activation delay increase. The possible maximum activation delay was 17 second. (author)

Files

53122410.pdf

Files (12.8 MB)

Name Size Download all
md5:ea3db12ae8f216d00e1ff21ca9adad3e
12.8 MB Preview Download
Part of:
Nuclear Safety Seminar Proceeding 2018, Enhanced Radiation Protection Optimization in Nuclear Control Integrated

Additional details

Additional titles

Original title (Indonesian)
Optimisasi dosis radiasi pemeriksaan CT scan thorax dengan pengaturan delay aktivasi bolus triggering (studi di instalasi radiologi RSUD DR Moewardi)

Publishing Information

Publisher
Nuclear Energy Regulatory Agency
Imprint Place
Jakarta (Indonesia)
Imprint Title
Nuclear Safety Seminar Proceeding 2018, Enhanced Radiation Protection Optimization in Nuclear Control Integrated
Imprint Pagination
502 p.
Journal Page Range
p. 358-364
ISSN
1412-3258
Report number
INIS-ID--104

Conference

Title
Nuclear Safety Seminar 2018, Enhanced Radiation Protection Optimization in Nuclear Control Integrated
Original Conference Title
Seminar Keselamatan Nuklir 2018, Peningkatan Optimisasi Proteksi Radiasi dalam Pengawasan Ketenaganukliran yang Terpadu
Dates
2 Aug 2018
Place
Malang (Indonesia)

INIS

Country of Publication
Indonesia
Country of Input or Organization
Indonesia
INIS RN
53122410
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ACCURACY; CAT SCANNING; CHEST; HOSPITALS; IMAGES; RADIATION DOSES; RADIOLOGY
Descriptors DEC
BODY; BUILDINGS; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; DOSES; MEDICAL ESTABLISHMENTS; MEDICINE; NUCLEAR MEDICINE; TOMOGRAPHY

Optional Information

Notes
17 refs.; 6 tabs.; 2 figs. Imprint:Prosiding Seminar Keselamatan Nuklir 2018, Peningkatan Optimisasi Proteksi Radiasi dalam Pengawasan Ketenaganukliran yang Terpadu