Published June 2007 | Version v1
Journal article

Correlation between semiquantitative myocardial perfusion score and absolute myocardial flow in 13N-ammonia PET

  • 1. Chonnam National University Hospital, Hwasun (Korea, Republic of)
  • 2. Chonnam National University Medical School, Gwangju (Korea, Republic of)
  • 3. Seoul National University College of Medicine, Seoul (Korea, Republic of)

Description

13N-ammonia is a well known radiopharmaceutical for the measurement of a myocardial blood flow (MBF) non-invasively using PET-CT. In this study, we investigated a correlation between MBF obtained from dynamic imaging and myocardial perfusion score (MPS) obtained from static imaging for usefulness of cardiac PET study. Twelve patients (11 males, 1 female, 57.9 ± 8.6 years old) with suspicious coronary artery disease underwent PET-CT scan. Dynamic scans (6 min: 5 sec X 12, 10 sec X 6, 20 sec X 3, and 30 sec X 6) were initiated simultaneously with bolus injection of 11 MBq/kg 13N-ammonia to acquire rest and stress image. Gating image was acquired during 13 minutes continuously. Nine-segment model (4 basal walls, 4 mid walls, and apex) was used for a measurement of MBF. Time activity curve of input function and myocardium was extracted from ROI methods in 9 regions for quantification. The MPS were evaluated using quantitative analysis software. To compare between 20-segment model and 9-segment model, 6 basal segments were excluded and averaged segmental scores were used. There are weak correlation between MBF (rest, 0.18-2.38 ml/min/g; stress, 0.40-4.95 ml/min/g) and MPS (rest 22-91%, stress, 14-90%), however the correlation coefficient between corrected MBF and MPS in rest state was higher than stress state (rest r=0.59; stress r=0.80). As a thickening increased, correlation between MBF and MPS also showed good correlation at each segments. Corrected and translated MPS as its characteristics using 13N-ammonia showed good correlation with absolute MBF measured by dynamic image in this study. Therefore, we showed MPS is one of good indices which reflect MBF. We anticipate PET-CT could be used as useful tool for evaluation of myocardial function in nuclear cardiac study

Additional details

Publishing Information

Journal Title
Nuclear Medicine and Molecular Imaging
Journal Volume
41
Journal Issue
3
Series
20 refs, 3 figs, 3 tabs
Journal Page Range
p. 194-200
ISSN
1975-129X

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
39032730
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BLOOD FLOW; CORRELATIONS; DIAGNOSIS; MYOCARDIUM; POSITRON COMPUTED TOMOGRAPHY
Descriptors DEC
BODY; CARDIOVASCULAR SYSTEM; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; EMISSION COMPUTED TOMOGRAPHY; HEART; MUSCLES; ORGANS; TOMOGRAPHY