Published 2009
| Version v1
Miscellaneous
Beam current measurement and beam positioning for baby-ebm
Creators
- 1. Malaysian Nuclear Agency, Bangi (Malaysia). Technical Support Div.
Description
This paper describes the electron beam detection of Baby EBM. The detection is divided by two categories; beam current measurement and beam positioning under the scanning window. The beam detector system was completely fabricated and tested and the detector was able to detect the electron beam of Baby EBM. It has been found that the beam current of this EBM is 1.62 mA for energy of 0.14 MeV. A higher beam current can be obtained if a proper cooling system to the window foil is installed. (Author)
Availability note (English)
Available from Malaysian Nuclear Agency Document Delivery Center, Ainon@nuclearmalaysia.gov.myAdditional details
Publishing Information
- Imprint Pagination
- 9 p.
Conference
- Title
- Nuclear Malaysia Technical Convention 2009
- Dates
- 6-8 Oct 2009
- Place
- Bangi (Malaysia)
INIS
- Country of Publication
- Malaysia
- Country of Input or Organization
- Malaysia
- INIS RN
- 40107222
- Subject category
- S43: PARTICLE ACCELERATORS; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- BEAM CURRENTS; COOLING SYSTEMS; ELECTRON BEAMS; RADIATION DETECTION; RADIATION DETECTORS
- Descriptors DEC
- BEAMS; CURRENTS; DETECTION; ENERGY SYSTEMS; LEPTON BEAMS; MEASURING INSTRUMENTS; PARTICLE BEAMS
Optional Information
- Notes
- NTC09-1033