Published 2011 | Version v1
Journal article

The effect of cooling rate of cooling system on centrifuge machine performance

  • 1. Atomic Energy Organization of Iran, Nuclear Science and Technology Research Institute, Nuclear Fuel Cycle Research School, Tehran, Sharif University of Technology, Faculty of Energy, Tehran (Iran, Islamic Republic of)
  • 2. Atomic Energy Organization of Iran, Nuclear Science and Technology Research Institute, Nuclear Fuel Cycle Research School, Tehran (Iran, Islamic Republic of)
  • 3. Sharif University of Technology, Faculty of Energy, Tehran (Iran, Islamic Republic of)

Description

In this paper, the effect of cooling rate of a cooling system on performance of a centrifuge machine has been studied experimentally. The cooling rate is increased by temperature variation and volumetric flow rate of the inlet water to the cooling system. The results showed that the effect of cooling rate on separative work unit, heads and tails separation factors i.e. α and β are negligible. Also, if the cooling rate is less than a minimum value, the heat produced by moving machine elements cannot be dissipated and some elements of machine may be destroyed.

Availability note (English)

Available from Atomic Energy Organization of Iran

Additional details

Additional titles

Original title (Persian)
Tasir-e bar-e boroodati-e sistem-e khonak konande bar rooye amalkard-e mashin-e santrifioozh

Publishing Information

Journal Title
Journal of Nuclear Science and Technology
Journal Issue
no.55
Journal Page Range
p. 1-7
ISSN
1735-1871