Experimental and Monte Carlo assessment of activity pattern with voxel phantoms for 30 years old actinides wound contaminations
Creators
- 1. Institut de Radioprotection et de Surete Nucleaire (IRSN), Laboratoire d'Evaluation de la Dose Interne, IRSN/DRPH/SDI/LEDI BP 17, F-92262 Fontenay-aux-Roses Cedex (France)
- 2. Burnasyan Federal Medical Biophysical Center of Federal Medical Biological Agency (FMBC), Zhivopisnaya str., 46, 123182, Moscow (Russian Federation)
- 3. Universite Paris XI, Master Degree in Medical Physics, 78 rue du General Leclerc, 94270 Le Kremlin-Bicetre (France)
Description
In vivo measurements have been performed with a devoted four Germanium detector system on two male patients presenting a 30 years old wound contamination by Americium and Plutonium isotopes. This paper presents the measurements and discusses their interpretation when only minimum hypothesises about the internal activity distribution are used. The measurements have been processed after the construction of voxelized phantoms of the measured body parts and Monte Carlo (MC) calculations of organ and detector specific counting efficiencies. The phantoms construction and MC calculations were assisted by the OEDIPE software and the reliability of the modeling has been controlled by the comparison of the measured and simulated efficiencies for well known sources. Mainly based on measurements at the knee level the 241Am specific bone activity is found to be (0.27 ± 23%) Bq/g for the first patient, and (0.04 ± 20%) Bq/g for the second one. Using measurements at the thorax level no activity can be detected in the lungs. For the first patient the liver activity is found to be between 410 and 460 Bq, the activity of the axillary, thoracic airways and trunk lymph nodes depends on the retained hypothesis, but a reasonable assessment for the axillary lymph nodes is between 100 and 350 Bq. For the second patient the liver activity is found to be (90 ± 20%) Bq and the activity of axillary lymph nodes (300 ± 20%) Bq, no activity can be detected in the lungs but a residual activity in thoracic airways lymph nodes can be suspected. (author)
Additional details
Identifiers
Publishing Information
- Publisher
- IAEA
- Imprint Place
- Vienna (Austria)
- ISBN
- 978-92-0-105410-4
- Imprint Title
- Proceedings of IRPA12: 12. Congress of the International Radiation Protection Association: Strengthening Radiation Protection Worldwide - Highlights, Global Perspective and Future Trends
- Imprint Pagination
- vp.
- Series
- Proceedings Series
- Journal Page Range
- 9 p.
- ISSN
- 0074-1884
Conference
- Title
- 12. International congress of the International Radiation Protection Association (IRPA): Strengthening radiation protection worldwide - Highlights, Global Perspective and Future Trends
- Acronym
- IRPA 12
- Dates
- 19-24 Oct 2008
- Place
- Buenos Aires (Argentina)
INIS
- Country of Publication
- Austria
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 42072474
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- AMERICIUM 241; BONE JOINTS; CHEST; CONTAMINATION; GE SEMICONDUCTOR DETECTORS; LIVER; LUNGS; LYMPH NODES; MONTE CARLO METHOD; PHANTOMS; PLUTONIUM ISOTOPES; SIMULATION; WOUNDS
- Descriptors DEC
- ACTINIDE NUCLEI; ALPHA DECAY RADIOISOTOPES; AMERICIUM ISOTOPES; BODY; CALCULATION METHODS; DIGESTIVE SYSTEM; DISEASES; GLANDS; HEAVY NUCLEI; INJURIES; ISOTOPES; LYMPHATIC SYSTEM; MEASURING INSTRUMENTS; MOCKUP; NUCLEI; ODD-EVEN NUCLEI; ORGANS; RADIATION DETECTORS; RADIOISOTOPES; RESPIRATORY SYSTEM; SEMICONDUCTOR DETECTORS; SKELETON; SPONTANEOUS FISSION RADIOISOTOPES; STRUCTURAL MODELS; YEARS LIVING RADIOISOTOPES
Optional Information
- Notes
- 19 refs, 4 figs Imprint:This CD-ROM is attached to the printed publication
- Secondary number(s)
- STI/PUB--1460 (Companion CD)