Analysis of absorbed dose in cervical spine scanning by computerized tomography using simulator objects
Description
The Computed tomography (CT) has become an important diagnostic tool after the continued development of Multidetector CT (MDCT), which allows faster acquisition of images with better quality than the previous technology. However, there is an increased radiation exposure, especially in examinations that require more than one acquisition, as dynamic exams and enhancement studies in order to discriminate low contrast soft tissue injury from normal tissue. Cervical spine MDCT examinations are used for diagnosis of soft tissue and vascular changes, fractures, dysplasia and other diseases with instability, which guide the patient treatment and rehabilitation. This study aims at checking the absorbed dose range in the thyroid and other organs during MDCT scan of cervical spine, with and without bismuth thyroid shield. In this experiment a cervical spine MDCT scan was performed on anthropomorphic phantoms, from the occipital to the first thoracic vertebra, using a 64 and a 16 – channel CT scanners. Thermoluminescent dosimeters were used to obtain the absorbed dose in thyroid, lenses, magnum foramen and breasts of the phantom. The results show that the thyroid received the highest dose, 60.0 mGy, in the female phantom, according to the incidence of the primary X-ray beam. The absorbed doses in these tests showed significant differences in the evaluated organs, p value < 0.005, except for the magnum foramen and breasts. With the bismuth thyroid shield applied on the female phantom, the doses in the thyroid and in the lenses were reduced by 27% and 52%, respectively. On the other hand, a reduction of 23.3% in the thyroid and increasing of 49.0% in the lens were measured on the male phantom. (author)
Files
49042010.pdf
Files
(2.7 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:7a966dad3fb1f2e271f1bf3787e01bcc
|
2.7 MB | Preview Download |
Additional details
Additional titles
- Original title (Portuguese)
- Análise de dose absorvida em varreduras de coluna cervical por tomografia computadorizada utlizando objetos simuladores
Publishing Information
- Imprint Pagination
- 80 p.
- Report number
- INIS-BR--20319
INIS
- Country of Publication
- Brazil
- Country of Input or Organization
- Brazil
- INIS RN
- 49042010
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Thesis
- Descriptors DEI
- ABSORBED RADIATION DOSES; COMPUTERIZED TOMOGRAPHY; CRYSTALLINE LENS; DOSIMETRY; MAMMARY GLANDS; PHANTOMS; RADIATION DOSE RANGES; SPINAL CORD; THERMOLUMINESCENT DOSEMETERS; THYROID
- Descriptors DEC
- BODY; CENTRAL NERVOUS SYSTEM; DIAGNOSTIC TECHNIQUES; DOSEMETERS; DOSES; ENDOCRINE GLANDS; EYES; FACE; GLANDS; HEAD; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS; MOCKUP; NERVOUS SYSTEM; ORGANS; RADIATION DOSES; SENSE ORGANS; STRUCTURAL MODELS; TOMOGRAPHY