Published 2001 | Version v1
Report Open

Dosimetric response of united, commercially available CTA foils for 60Co gamma rays

Description

The usefulness of two kinds of untinted CTA foils: Fuji CTR-125 dosimetric foil and technical CTA-T foil, produced by 'Zaklady Chemiczne, 'Gorzow Wielkopolski' as support for light-sensitive layers of amateur photo-films, for 60Co gamma ray dosimetry was investigated. In spite of rather bad physical parameters of the technical foil (spread of foil thickness, high and different initial absorbance) the dosimetric response of both foils for 60Co gamma rays was similar. The CTA-T foil can be used for routine dosimetry providing that dosimetric signals have to be calculated exactly as recommended by the ASTM (American Society for Testing and Materials) standard, i.e. as the difference of absorbance of irradiated and (the same) non-irradiated foil. Any other approach may lead to high errors of dose evaluation. The last is true also for other CTA foils, especially after long self-life. (author)

Availability note (English)

Available from INIS in electronic form

Files

34001927.pdf

Files (1.5 MB)

Name Size Download all
md5:5459f4092101457442768930343518f1
1.5 MB Preview Download

Additional details

Additional titles

Original title (Polish)
Odpowiedz dozymetryczna nie barwionych folii z trioctanu celulozy (CTA) na promieniowanie

Publishing Information

Imprint Pagination
24 p.
ISSN
1425-7351
Report number
INCT--11/B/01

Optional Information

Notes
11 refs, 7 figs, 5 tabs