Published 1976 | Version v1
Journal article

Radioimmunoassay of secretin in human plasma

  • 1. Ullevaal Sykehus, Oslo (Norway)
  • 2. Aker Sykehus, Oslo (Norway)

Description

A radioimmunoassay is presented which employs 125I-labelled synthetic secretin, antibody against synthetic secretin, and standards prepared from pure natural porcine secretin. Secretin to be measured was extracted into methanol from heparinized plasma containing aprotinin, which together with cysteine hydrochloride was used as stabilizer throughout the assay. With polyethylene glycol separation, a within assay precision of 10% at 17 pmol/1 was found. The between assay precision was 15% at 17 pmol/1 and thelimit of detection 2.5 pmol/1 plasma. Accuracy was 70-85%. The immunoreactive secretin levels in human plasma increased from 4.5+/-0.5 pmol/1 (mean+/-S.E.M.) to 19.5+/-7.5 pmol/1 (mean+/-S.E.M.) after duodenal acidification (n=5). Pancreatic flow rate increased from 0.5+/-0.1 ml/min (mean+/-S.E.M.) to 4.8+/-0.5 ml/min (mean+/-S.E.M.), and bicarbonate output from 9.6+/-1.8 mumol/min (mean+/-S.E.M.) to 268+/-51 mumol/min (mean+/-S.E.M.) after duodenal acidification.

Additional details

Identifiers

Publishing Information

Journal Title
Scandinavian Journal of Gastroenterology
Journal Volume
12
Journal Issue
4
Series
Scand. J. Gastroenterol.
Journal Page Range
481-488
ISSN
0036-5521

Conference

Title
10. Scandinavian conference on gastroenterology.
Dates
9 Sep 1976.
Place
Aarhus, Denmark.

Optional Information

Notes
In summary form only.; Updated automatically by Metadata and Full-Text Enrichment Agent