Published 1977
| Version v1
Book
Heavy water management at the Rajasthan Atomic Power Station
Description
Due to the escalation in price of heavy water and its non-availability in the international market, the management of heavy water in PHWR type reactors must necessarily achieve a drastic reduction in heavy water losses for economic operation of such nuclear power plants. Various causes which led to the acute escapes of heavy water in Rajasthan Atomic Power Station (RAPS) are listed. Performance of the upgrader for upgrading of the recovered downgraded water is given. (M.G.B.)
Additional details
Publishing Information
- Publisher
- Department of Atomic Energy.
- Imprint Place
- Bombay
- Imprint Title
- Symposium on operating experience of nuclear reactors and power plants [held during] February 7-9, 1977 [at] Bombay [Invited talks and contributed papers]
- Journal Page Range
- p. 423-426.
Conference
- Title
- Symposium on operating experience of nuclear reactors and power plants.
- Dates
- 7 - 9 Feb 1977.
- Place
- Bombay, India.
INIS
- Country of Publication
- India
- Country of Input or Organization
- India
- INIS RN
- 10470732
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- HEAVY WATER; LEAKS; LOSSES; MANAGEMENT; PURIFICATION; RAJASTHAN-1 REACTOR; RAJASTHAN-2 REACTOR; REACTOR COOLING SYSTEMS
- Descriptors DEC
- CANDU TYPE REACTORS; COOLING SYSTEMS; HEAVY WATER COOLED REACTORS; HEAVY WATER MODERATED REACTORS; HYDROGEN COMPOUNDS; NATURAL URANIUM REACTORS; OXYGEN COMPOUNDS; PHWR TYPE REACTORS; POWER REACTORS; PRESSURE TUBE REACTORS; REACTOR COMPONENTS; REACTORS; THERMAL REACTORS; WATER